Filter Results By:

Products

Applications

Manufacturers

Clamp Meters

combine meter and current probe into integrated instrument.


Showing results: 286 - 300 of 306 items found.

  • Test Leads

    AL-34WB 10A - Standard Electric Works Co., Ltd

    ● Wire length: 1m approx.    Silicone insulated wire (700mm) with wire connected to straight input plugs (150mm PVC wire), and wire for clamp (150mm PVC wire).● Outside diameter of silicone insulated wire: 6.4mm   Outside diameter of PVC wire: 4mm● Input plug color: Red•Green•Black•Blue  ● Current rating: 10A● Voltage rating: 300V● Designed for Milliohm meter, Micro-ohm meter, Low resistance measurement with high current injection. ● Conductor size: 40mm maximum● Safety standard: IEC/EN 61010-031  CAT IV 300V

  • Test Leads

    AL-34WB - Standard Electric Works Co., Ltd

    ● Wire length: 1.2m approx.    Silicone insulated wire (1000mm) with wire connected to straight input plugs (130mm PVC wire), and wire for clamp (100mm PVC wire). ● Outside diameter of silicone insulated wire: 5mm   Outside diameter of  PVC wire: 3.5mm● Input plug color: Red•Green•Black•Blue  ● Current rating: 5A● Voltage rating: 300V● Designed for Milliohm meter, Micro-ohm meter, Low resistance measurement with high current injection. ● Conductor size: 40mm maximum● Safety standard: IEC/EN 61010-031  CAT IV 300V

  • Energized Cable Sensor

    Hubbell Power Systems Inc

    The purpose of the Energized Cable Sensor is to allow the lineman to readily determine whether a URD cable is energized. The sensor consists of an amplifier which is designed to give a meter reading when the small AC voltage between the semi-conductive sheath and the concentric neutral of the energized URD cable is applied to the test probe. The amplifier is housed in a rugged phenolic case. Sensor may be used to check for energized condition on concentric-neutral cable below an elbow without test points. At cable mid-span (left), hose clamps bridge all strands of concentric neutral at the test location. Sensor’s neutral lead clips to one of the hose clamps. Tip on probe lead contacts only semi-conductive cable sheath to test for voltage presence.

  • AC Line Splitter

    1937 - Peaceful Thriving Enterprise Co Ltd

    The AC line splitter is a helpful testing device for electrician. Electrician can measure the current with clamp meter through the X1 and X10 measuring rings. X1 is 1:1 measurement, and X10 is ten times (1:10) of the actual current, which is helpful for small current measurement. This device also combines the function of socket tester and GFCI tester, which means electrician can use this tester to test socket and load at the same time.

  • Multi-purpose Tester

    DEL-101 - Standard Electric Works Co., Ltd

    ● Mains wiring polarity check.● ELCB/RCD testing.● Measuring ear for line current.● Measuring ear for leakage current.● Helps calculate insulation resistance.● Helps calculate power consumption.● Helps fault finding of standing earth fault.● Fused main adapter.● Appliance testing (with the aid of a clamp meter).● Fused appliance socket.● No batteries required.● HRC fuse inside.● Fused, color-coded universal test sockets.● Universal mains IEC Lead.

  • Hi-Z HV AC Voltmeters

    B-1013 - ROSS ENGINEERING CORPORATION

    *25kV, 50kV or 100kV Meter with integral line to ground Probe*Phasing or line to line with additional Probe*Optional 6ft or 9ft Collapsible Hotsticks*Voltage source for testing Voltmeters and Probes*Optional test point contamination indicating Megmeter®*High voltage cable clamps or hooks*Heavy duty carrying case

  • Sensor Unit for High Precision Current Sensors

    CT9557 - HIOKI E.E. Corp

    Hioki pull-through current sensors and clamp on current probes are best-in-class current sensing devices for use with power meters, Memory HiCorders and high performance oscilloscopes. The CT9555 is 4-channel sensor unit and power adapter for any of the CT686x series, 9709 and CT684x series current sensors and probes that provides waveform and RMS output.

  • Mini Digital Clamp Tester (CE)

    M-140HC - MULTI MEASURING INSTRUMENTS Co., Ltd.

    *Easy!:Measurale Load Current at high voltage CV/CVT cables with grounding lines for shield phase.*Epoch-Making!:Can measure phase current of CVT cable just by putting CT head on to the conductors as well as CV cable just by clamping CT to the conductors in a lump.*Low Cost!:Can measure line/leakage current in the same manner as ordinary clamp meters.

  • 1000 Amp Clamp with IR Thermometer

    FLIR CM78 - Teledyne FLIR

    The FLIR CM78 is a True RMS industrial clamp meter for the electrician who works on high-powered equipment and temperature systems and needs a safe, capable combination tool. An integrated IR thermometer provides fast non-contact measurements on panels, conduits, and motors. FLIR Tools Mobile connects the FLIR CM78 to your compatible smartphones and tablets via Bluetooth®, and METERLiNK® technology wirelessly integrates electrical readings on your infrared image with FLIR thermal cameras.

  • Portable Electricity Meter Testers

    EE-120A-1S - EMSYST Ltd

    The EE-120A-1S unit consists of a single-phase energy standard class 0.1 and current load up to 120A. The unit performs testing of all types single-phase electricity meters using the voltage of the site. The meter error can be measured for active, reactive or apparent energy, in Manual Mode or with predefined Test Plans using the keyboard and the LCD display on the panel. Register Test, Starting Current Test and No Load Test can be performed too. The energy standard of the system can be used without the phantom load to test meters with customer load and perform analysis of the site – with direct measurement or with optional current clamps.

  • Portable Electricity Meter Testers

    EE-120A-3S - EMSYST Ltd

    The EE-120A-3S unit consists of a three-phase energy standard class 0.1 and current load up to 120A. The unit performs testing of all types of electricity meters using the voltages of the network. The meter error can be measured for active, reactive or apparent energy in Manual Mode or with predefined Test Plans using the keyboard and the LCD display on the panel. Maximum Demand Test, Register Test, Starting Current Test and No Load Test can be performed too. The energy standard of the system can be used without the phantom load to test meters with customer load and perform analysis of the three-phase network – with direct measurement or with optional current clamps.

  • 1000A AC/DC True RMS Clamp/DMM + IR Thermometer

    Extech EX840 - Extech Instruments Corporation

    This CAT IV True RMS clamp meter features a built-in IR thermometer with laser pointer for non-contact surface measurements from -58 to 518 °F (-50 to 270 °C). Clamp measures AC current up to 1000 Amp with a maximum resolution of 0.1 Amp. The 1.7-inch jaw fits around conductors up to 750MCM. Peak hold captures motor inrush currents and other surges. Data hold and auto power off functions. Other functions include AC/DC Voltage, resistance, Type K thermometer, capacitance and frequency. Complete with test leads, Type K temperature probe, 9 Volt battery and case.

  • AC Line Splitter

    Extech 480172 - Extech Instruments Corporation

    This Extech 480172 Line Splitter provides a fast and easy way to “open” standard 120 Volt AC electrical lines, eliminating the need to cut off the plug and separate the conductors. When connected between a 120 Volt AC outlet and a device under test, this splitter separates the hot/live conductor from the neutral and ground, which enables users to measure AC current up to 15 Amp on a two-wire or three-wire lines using a clamp meter. This splitter also features two Voltage Test jacks so that voltage can be measured using a multimeter.

  • ELECTRICAL TEST Kit

    1021 TK - Standard Electric Works Co., Ltd

    2950 CL ● Pocket size.● 4000 counts.● Full automatic measurement : Voltage measurement. Current measurement. Resistor measurement.● Data hold function.● Continuity check.● Diode measurement.● Select function.● Low battery indication.● Auto off function.● Flashlight (auto off in 1 minute). ALS-2 ● Use with any clamp meter.● x10 mode allows for more accurate measurements of low amperage devices.● x1 mode allows for direct reading.● 4mm voltmeter input jacks.● Integrated ground conductor.● 10 amp capacity.● 10cm plug cord for greater flexibility.

  • Dual Temperature

    Fieldpiece Instruments, Inc

    The Fieldpiece Dual-Temperature Accessory, model ATH4, measures two temperatures simultaneously using the included k-type, wrap tab beaded thermocouples. The technology inside the ATH4 provides superior temperature compensation in rapidly changing environments commonly found while performing field service. Use the ATH4 to find Delta T and just about any temperature split you want to measure. Displays T1, T2 and T1-T2 on your Fieldpiece meter, handle or data logger. It is included with the HVAC Guide® System Analyzer to get target superheat and for the Target Evaporator Exit Temperature test. Fieldpiece offers a wide variety of k-type thermocouples for various HVAC specific applications. Use pipe clamp T/Cs with the ATH4 to check for blocked filters.

Get Help